Standing seam façade on a damp proof system
See chapter 4 for standard and alternative built ups.
Damp proof façade built up with NedZink standing seam system.
The construction of the façade is built up as follows, beginning on the inside:
1. Building structure
2. Damp control course μd ≥ 150
3. Insulation layer, according to thermal requirements
4. Wooden substructure
5. Separating layer
6. Standing seam system
Standing seam system details damp proof vertical bay
Standing seam system details damp proof horizontal bay.